Hardware Housing Specification
- Vandal Proof Equipment Housing designed for indoor or outdoor installation in hostile environments.
- ENB hardware available in a range of sizes from 15” to 32”.
- Non-Touch Screen 3 illuminated button based interactive control system. (To reduce contamination and cleaning)
- All parts are field serviceable for on-site maintenance and include Screen Housing Back / Front / Glass / Antennas / PSU / Logic Boards / Comms Modules / Interactive Systems
Display Specification
- Full HD Display 1920 x 1080
- Viewing Angle H >177 V > 177
- Screen Brightness 350 NIT
- 24/7 Operation
- Timed operation with ability to shut down display during customer specified hours.
Communications Specification
- Integrated LTE / 4G Mobile Communications
- Supports Wi-Fi and Ethernet
- LoRa Remote Management for system diagnosis,
power down and restart - LoRa Base Station for the interconnection of other
LoRa sensors to assist in other building management applications. - Will Operate Offline during communications
failure / blackout.
Energy Consumption
- Max 55W
failure / blackout.
ENB System Reports
- Display Status, Modem Comms Status, Device Temperature
Media Software Specification
- Secure Communications to Cloud based Management Server.
- User Media Upload Facility with support for JPEG,
PNG, GIF, MP3, MP4 - User Media Management
- Support for ENB Groups
- Support for Multiple Playlists ENB Group Playlist
and / or additional Individual ENB Playlist - Marquee Player for immediate user generated notifications
- Support for Media Content Categories for use with Interactive Capabilities
- Support for the interactive storage and display
of non-playlist media. - Support for Interactive Surveys
- Report Interactive Usage Stats
- Device Location and Mapping
- Support Auto Content options including News, Sports News, Weather, Real Time Transport Information
Device Management Software
- ENB Auto Diagnostics and Self Restart
- ENB Auto Media Player Restart
- ENB Auto Comms restart
Hardware and Software Support
- 24/7 System Monitoring
- Remote ENB Support
- On Site Hardware and Software Support
- London based support team
Physical Dimensions Excluding Antennas
15” ENB | 22” ENB | 32” ENB | |
---|---|---|---|
Width | 475mm | 770mm | 1015mm |
Height | 275mm | 401mm | 520mm |
Depth | 65mm | 80mm | 90mm |